Benchtop and portable instruments for drinking water, groundwater, irrigation water, wastewater and aquaculture, from routine pH checks to nutrient and metal analysis.

Water Quality Testing Equipment

Knowing what is in the water

Water quality testing equipment measures the chemical, physical and microbiological condition of water. Photometric analysers cover nearly a hundred parameters, including COD, ammonia nitrogen, total phosphorus and total nitrogen, dedicated testers target individual heavy metals and compounds, turbidity meters assess clarity and suspended solids, and field kits culture coliform and other bacteria on site. Electrochemical meters measure pH, conductivity, TDS, ions and dissolved oxygen. Water utilities, environment ministries, wastewater plants, irrigation authorities, aquaculture farms, universities and food plants use them daily. ASFAN supplies, installs and supports water testing equipment and helps specify complete water laboratories.

Water Quality Testing Equipment

Benchtop Multi-Parameter Water Quality Analyzer

Benchtop Multi-Parameter Water Quality Analyzer

Passes a single wavelength of light through the sample and, according to the Lambert-Beer law, calculates the concentration of a substance from the measured absorbance. Measures concentration, absorbance and transmittance for nearly 100 water quality parameters.

  • Selectable wavelengths340, 420, 440, 470, 520, 540, 560, 610, 630, 660, 680, 700 nm
  • Absorbance errormax 0.005
  • Measurement errorgenerally 5%, individual 10%
  • Absorbance range-2.00 to 2.000
Features & full specifications

Key features

  • Nearly 100 water quality parameters; results can be saved, printed, queried or uploaded to a computer
  • Selectable measurement wavelength
  • Backup of user-calibrated curves and data records, recoverable after accidental loss
  • Built-in calibration function eliminates long-term drift
  • 5-inch color touch screen
  • Light intensity adjustable in 16 levels
  • Users can add, calibrate and save their own curves
  • Full calibration history can be queried (curve equation, standards, absorbance, time, operator)

Technical specifications

Selectable wavelengths340, 420, 440, 470, 520, 540, 560, 610, 630, 660, 680, 700 nm
Absorbance errormax 0.005
Measurement errorgenerally 5%, individual 10%
Absorbance range-2.00 to 2.000
Power supplyAC220V (165V~240V), 30W
Instrument size400x310x158mm
Instrument weight5kg
Working environment10-35°C, humidity ≤90%
Request a quote
COD, Ammonia Nitrogen, Total Phosphorus and Total Nitrogen Analyzer

COD, Ammonia Nitrogen, Total Phosphorus and Total Nitrogen Analyzer

Directly measures COD, ammonia nitrogen, total phosphorus and total nitrogen in water samples. COD uses fast digestion optical method, ammonia nitrogen the Nessler reagent method, total phosphorus the molybdenum blue method and total nitrogen the alkaline potassium persulfate method.

  • COD range5~2000 mg/L (extendable to 20000 mg/L)
  • Ammonia nitrogen range0.02~25 mg/L
  • Total phosphorus range0.00~10 mg/L
  • Total nitrogen range0.10~150 mg/L
Features & full specifications

Key features

  • High-brightness, long-life cold light source with high stability and repeatability
  • Separate digester and main unit so digestion does not affect optical stability
  • PID-controlled digester temperature and timing
  • Free setting of digestion temperature and time
  • Standard version stores 300 curves and 1000 records; upgraded version stores 3500 curves and 100000 records with improved optics
  • 3.5-inch color touch screen digester display

Available configurations

  • Standard version: 300 curves, 1000 records
  • Upgraded version: 3500 curves, 100000 records, improved optical stability

Technical specifications

COD range5~2000 mg/L (extendable to 20000 mg/L)
Ammonia nitrogen range0.02~25 mg/L
Total phosphorus range0.00~10 mg/L
Total nitrogen range0.10~150 mg/L
Indication error≤±5% (COD, total phosphorus, total nitrogen), ≤±3% (NH3-N)
Repeatability≤±3%
Anti-chlorine interference≤2000 mg/L (COD)
Digestion temperatureCOD 165°C, total phosphorus 120°C, total nitrogen 125°C (settable to 200°C)
Batch volume16 water samples (optional 20, 25, 36)
Main unit400mm × 310mm × 158mm, 5kg
Request a quote
Turbidity, Color and Suspended Solids Meter

Turbidity, Color and Suspended Solids Meter

Measures turbidity, chroma and suspended matter in drinking water, surface water, groundwater and other water.

  • Turbidity range0.00~400 NTU
  • Chroma range0.0 to 500 CPU
  • Suspended matter range0-1000 mg/L
  • Accuracy≤±2% F.S (turbidity, suspended matter), ≤±3% F.S (chroma)
Features & full specifications

Key features

  • Cold light and monochromatic light source with excellent optical stability
  • Large-screen LCD with integrated settings, calibration and recording
  • V/F conversion, software redundancy and software trap for strong anti-interference
  • Stores 10 working curves and 500 records; user calibration; data retained on power loss
  • Built-in printing

Technical specifications

Turbidity range0.00~400 NTU
Chroma range0.0 to 500 CPU
Suspended matter range0-1000 mg/L
Accuracy≤±2% F.S (turbidity, suspended matter), ≤±3% F.S (chroma)
Repeatability≤3%
Optical stabilityabsorbance drift < 0.002A within 20 min
Dimensions340 × 250 × 130 mm
Weight4kg
Working environment5 to 40°C, ≤85%RH
Power supplyAC (220±22) V; (50±0.5) Hz
Request a quote
Single-Parameter Heavy Metal and Compound Water Tester

Single-Parameter Heavy Metal and Compound Water Tester

Uses narrow-band laser technology to produce a single wavelength; absorbance is measured by colorimetry under microcomputer control and the concentration is calculated automatically by the Lambert-Beer law. Configurable for one of many heavy metals, inorganic salts or other compounds.

  • Heavy metalscopper, manganese, nickel, aluminum, hexavalent chromium, total chromium, iron, cadmium, zinc, barium, mercury, beryllium, antimony, lead, molybdenum, silver, boron
  • Inorganic saltssulfate, phosphate, nitrate, nitrite, cyanide, sulfide, fluoride, chloride, silica
  • Other parametersiodine, arsenic, alkalinity, residual chlorine, hardness, chlorine dioxide, available chlorine, organics, ozone, anionic surfactant
Features & full specifications

Key features

  • Cold light and monochromatic light source, stable optics
  • Factory preset curves that can be queried; user calibration
  • Large LCD with integrated settings, calibration and recording
  • Software redundancy and software trap for anti-interference
  • Customizable measurement parameter

Technical specifications

Heavy metalscopper, manganese, nickel, aluminum, hexavalent chromium, total chromium, iron, cadmium, zinc, barium, mercury, beryllium, antimony, lead, molybdenum, silver, boron
Inorganic saltssulfate, phosphate, nitrate, nitrite, cyanide, sulfide, fluoride, chloride, silica
Other parametersiodine, arsenic, alkalinity, residual chlorine, hardness, chlorine dioxide, available chlorine, organics, ozone, anionic surfactant
Request a quote
Portable Multi-Parameter Water Quality Analyzer (Field Case)

Portable Multi-Parameter Water Quality Analyzer (Field Case)

A portable case-type analyzer for surface water, groundwater, source water, drinking water, sewage outlets, seawater and other water bodies. pH and conductivity are measured by electrochemical sensors, turbidity by light scattering (or scattering plus transmission), and other items by optical colorimetry.

  • Measurement itemsabout 60 items incl. COD, ammonia nitrogen, total/residual chlorine, phosphate, nitrite, nitrate, heavy metals, pH, dissolved oxygen, conductivity, suspended solids, turbidity, chroma
  • Curve storage300 curves
  • Record storage1000 records
  • Display5-inch color touch screen
Features & full specifications

Key features

  • Wavelength selected automatically, no calibration required
  • 5-inch color touch screen
  • Convenient for on-site inspection
  • Stores 300 curves and 1000 timestamped records
  • USB interface and PC data acquisition software
  • Cold light source with narrow-band interference optics
  • Power-off data protection and record printing
  • Rechargeable lithium battery with battery detection
  • One-click recovery of factory and user curves
  • Password-protected settings
  • Self-calibration to eliminate long-term drift

Technical specifications

Measurement itemsabout 60 items incl. COD, ammonia nitrogen, total/residual chlorine, phosphate, nitrite, nitrate, heavy metals, pH, dissolved oxygen, conductivity, suspended solids, turbidity, chroma
Curve storage300 curves
Record storage1000 records
Display5-inch color touch screen
InterfaceUSB
Powerrechargeable lithium battery
Request a quote
Portable COD, Ammonia Nitrogen, Total Phosphorus and Total Nitrogen Analyzer

Portable COD, Ammonia Nitrogen, Total Phosphorus and Total Nitrogen Analyzer

Uses high-temperature sealed catalytic digestion and monochromatic light for colorimetric measurement. Compact and easy to carry with its own lithium battery; digestion and colorimetry use the same tube without external power supply.

  • COD range5~2000 mg/L
  • Ammonia nitrogen range0.02~25 mg/L
  • Total phosphorus range0.00~10 mg/L
  • Total nitrogen range0.05~100 mg/L
Features & full specifications

Key features

  • Digester separate from the analyzer; PID control of temperature and timing
  • Low-power 16-bit single-chip system, standby time over 6 months
  • Power options: car cigarette lighter, high-capacity portable lithium battery or 220V
  • Imported cold light source with narrow-band filter, very stable optics
  • Large LCD display
  • Data retained on power loss
  • 30 standard curves and 199 timestamped measurements stored
  • USB port for PC reading or printing
  • Molded ABS housing, IP65 design: anti-corrosion, waterproof and dust-proof
  • High-strength carrying suitcase

Technical specifications

COD range5~2000 mg/L
Ammonia nitrogen range0.02~25 mg/L
Total phosphorus range0.00~10 mg/L
Total nitrogen range0.05~100 mg/L
Indication error≤±5% (COD, total nitrogen), ≤±3% F.S (ammonia nitrogen), ≤±5% F.S (total phosphorus)
Repeatability≤3%
Temperature control accuracy±0.5°C
Digestion timeCOD 15 min; total phosphorus and total nitrogen 30 min (adjustable 1 to 999 min)
Batch volume4 water samples (or 16 water samples)
WavelengthsCOD 420nm and 610nm, ammonia nitrogen 420nm, total phosphorus 700nm, total nitrogen 340nm
Dimensionsanalyzer 80 × 230 × 55 mm; digester 105 × 160 × 90 mm
Weightanalyzer 0.5kg; digester 1kg
Request a quote
Aquaculture Water Quality Analyzer

Aquaculture Water Quality Analyzer

Determines water quality parameters in aquaculture, including salinity, pH, dissolved oxygen, ammonia nitrogen, sulfide, nitrite, mercury and cadmium.

  • pH5.00-8.00
  • Salinity0.0-28.0
  • Dissolved oxygen0.10-10.0 mg/L
  • Ammonia nitrogen0.02-25.0 mg/L
Features & full specifications

Key features

  • Long-life light source and high-stability optical system for good repeatability
  • 10 standard curves and 500 measurements stored; data retained on power loss
  • Large LCD display
  • Built-in printing of current and historical records
  • USB interface to computer

Technical specifications

pH5.00-8.00
Salinity0.0-28.0
Dissolved oxygen0.10-10.0 mg/L
Ammonia nitrogen0.02-25.0 mg/L
Nitrite0.02-5.00 mg/L
Sulfide0.005-1.00 mg/L
Mercury0.002-0.5 mg/L
Cadmium0.01-0.5 mg/L
Indication error≤±5% (F.S)
Dimensions / weight340mm × 250mm × 130mm, 4kg
Request a quote
Portable Water Bacteria Detection Kit

Portable Water Bacteria Detection Kit

A portable microbiology kit with a multifunctional culture medium holder for detecting total bacteria, E. coli, fecal E. coli, fecal streptococcus, Salmonella and other items in water on site.

  • Portabilityequipment and consumables in a solid portable box
  • Culture conditions30 groups of custom culture temperatures, 20~50℃, custom duration, microbial recovery mode
  • Temperature controlthermistor pair with automatic temperature identification, cooling and temperature calibration
  • Filter membrane0.45 µm
Features & full specifications

Key features

  • Works with dry powder medium or prefabricated media
  • Automatic vacuum pump and filter kit with 0.45 µm membrane for on-site sample filtration
  • Holds 7 nutrient plates or 20 aluminum dishes at once
  • Timed reminders and automatic shutdown
  • Filter parts can be flame-sterilized at the sampling site
  • Screen or voice prompts, multiple languages

Technical specifications

Portabilityequipment and consumables in a solid portable box
Culture conditions30 groups of custom culture temperatures, 20~50℃, custom duration, microbial recovery mode
Temperature controlthermistor pair with automatic temperature identification, cooling and temperature calibration
Filter membrane0.45 µm
Capacity7 nutrient plates or 20 aluminum dishes
Request a quote
Benchtop pH Meter

Benchtop pH Meter

A benchtop pH/mV meter with a 6.0-inch high-resolution LCD, electrode stand, 1-3 point calibration with automatic buffer recognition and temperature compensation.

  • pH range-2.00 to 18.00 pH
  • pH resolution0.01 pH
  • pH accuracy±0.01 pH
  • Calibration pointsUp to 3
Features & full specifications

Key features

  • 6.0-inch high-resolution LCD
  • Auto-read and continuous-read modes
  • Auto-hold locks the measurement endpoint
  • 50 data sets stored per parameter
  • Reset to factory defaults
  • IP54 waterproof
  • 1-3 point calibration with standard (NIST buffer) recognition

Available configurations

  • Automatic temperature compensation version, measures pH / temperature (mV)
  • Manual temperature compensation version, measures pH / mV

Technical specifications

pH range-2.00 to 18.00 pH
pH resolution0.01 pH
pH accuracy±0.01 pH
Calibration pointsUp to 3
Standard recognitionNIST buffers
mV range-1999 to 1999 mV
mV resolution1 mV
mV accuracy±0.1 %FS
Temperature range-5 to 110 °C, 23 to 230 °F (automatic version)
Temperature accuracy±0.2
Request a quote
Benchtop Conductivity / TDS Meter

Benchtop Conductivity / TDS Meter

A benchtop conductivity meter with 6.0-inch LCD, 1-point calibration with standard recognition and settable cell constant; also reads TDS.

  • Conductivity range0.00 µS/cm to 200 mS/cm
  • Resolution0.01 µS/cm minimum; changes with range
  • Accuracy±1.0 % FS
  • Reference temperature25 °C
Features & full specifications

Key features

  • 6.0-inch high-resolution LCD
  • 1-point calibration with standard recognition
  • Settable cell constant
  • Automatic or manual temperature compensation
  • Auto-hold, 50 data sets per parameter
  • IP54 waterproof

Available configurations

  • Automatic temperature compensation version, measures EC / temperature (TDS)
  • Manual temperature compensation version, measures EC (TDS)

Technical specifications

Conductivity range0.00 µS/cm to 200 mS/cm
Resolution0.01 µS/cm minimum; changes with range
Accuracy±1.0 % FS
Reference temperature25 °C
Calibration pointsUp to 1
Standard recognition146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm
TDS range0.00 mg/L ~ 100 g/L
TDS resolution0.01 mg/L minimum; changes with range
TDS accuracy±1.0% FS
Temperature range-5 to 110 °C, 23 to 230 °F (automatic version)
Request a quote
Advanced Multi-Parameter Benchtop Meter

Advanced Multi-Parameter Benchtop Meter

A research-grade benchtop meter series with color touchscreen and an intelligent operating system for user, calibration, electrode, method and data management. Available as a full multi-parameter unit or as dedicated pH, conductivity, ion (ISE) or dissolved oxygen meters.

  • pH range-2.000 to 20.000 pH, accuracy ±0.002 pH
  • mV/ORP range-2000.00 to 2000.00 mV, accuracy ±0.1 mV or ±0.03%
  • ISE range0~19990, accuracy ±0.3%
  • Conductivity range0.000 µS/cm to 3000 mS/cm, accuracy ±0.5% FS
Features & full specifications

Key features

  • Color high-contrast LCD touchscreen
  • User, calibration, electrode, method and data management
  • Auto-read, timed-read and continuous-read
  • Automatic/manual temperature compensation
  • Auto-hold endpoint detection
  • Up to 1000 data sets per parameter (GLP-compliant)
  • Data analysis to review, compare and recalculate results
  • USB or RS-232 output to PC or printer
  • Automated measurement

Available configurations

  • Full multi-parameter: pH/EC/ISE/DO/temperature (mV/ORP/pX/resistivity/TDS/salinity/DO saturation)
  • pH meter: pH/temperature (mV/ORP)
  • Conductivity meter: EC/temperature (resistivity/TDS/salinity)
  • Ion meter: pH/ISE/temperature (mV/ORP/pX)
  • Dissolved oxygen meter: DO/temperature (DO saturation)

Technical specifications

pH range-2.000 to 20.000 pH, accuracy ±0.002 pH
mV/ORP range-2000.00 to 2000.00 mV, accuracy ±0.1 mV or ±0.03%
ISE range0~19990, accuracy ±0.3%
Conductivity range0.000 µS/cm to 3000 mS/cm, accuracy ±0.5% FS
Resistivity range5.00 Ω·cm ~ 100.00 MΩ·cm
TDS range0.000 mg/L ~ 1000 g/L, accuracy ±0.5%
Salinity range(0.00 ~ 8.00)% NaCl, accuracy ±0.1%
Dissolved oxygenpolarographic, 0.00 to 99.99 mg/L, accuracy ±0.1 mg/L; saturation 0.0 to 600%
Temperature-5 to 130 °C, accuracy ±0.1
Data storage / power1000 groups; AC adapter 100-240 VAC input, DC24V output
Request a quote
Portable Multi-Parameter Water Meter

Portable Multi-Parameter Water Meter

A handheld multi-parameter meter series with 3.5-inch LCD for pH, ORP, ion, conductivity, TDS, salinity and dissolved oxygen measurements, available as multi-parameter or single-parameter versions.

  • pH range-2.00 to 20.00 pH, accuracy ±0.02 pH
  • mV range-2000.00 to 2000.00 mV, accuracy ±0.3 mV or ±0.1% of reading
  • ISE range1E-9 to 9.999E9, accuracy ±0.5%, up to 5 calibration points
  • Conductivity range0.000 µS/cm to 500 mS/cm, accuracy ±1.0% FS
Features & full specifications

Key features

  • 3.5-inch LCD display
  • Auto-read, timed-read and continuous-read
  • Automatic/manual temperature compensation
  • Auto-hold endpoint detection
  • Up to 500 data sets per parameter (GLP-compliant)
  • USB communication
  • Auto power-off for longer battery life
  • Reset to factory defaults
  • IP65 waterproof

Available configurations

  • Multi-parameter: mV/pX/resistivity/TDS/salinity/DO saturation
  • Multi-parameter: pH/EC/ISE/temperature (mV/pX/resistivity/TDS/salinity)
  • pH meter: pH/temperature (mV)
  • Conductivity meter: EC/temperature (resistivity/TDS/salinity)
  • Dissolved oxygen meter: DO/temperature (DO saturation)

Technical specifications

pH range-2.00 to 20.00 pH, accuracy ±0.02 pH
mV range-2000.00 to 2000.00 mV, accuracy ±0.3 mV or ±0.1% of reading
ISE range1E-9 to 9.999E9, accuracy ±0.5%, up to 5 calibration points
Conductivity range0.000 µS/cm to 500 mS/cm, accuracy ±1.0% FS
Resistivity range5.00 Ω·cm ~ 20.00 MΩ·cm
TDS range0.00 mg/L ~ 300 g/L, accuracy ±1.0%
Salinity range(0.00 ~ 8.00)%, accuracy ±0.2%
Dissolved oxygenpolarographic, 0.00 to 50.00 mg/L, accuracy ±0.3 mg/L; saturation 0.0 to 300.0%
Temperature-5 to 110 °C, 23 to 230 °F, accuracy ±0.2
Data storage / power500 results each; rechargeable lithium battery, AC adapter 100-240 VAC input, DC5V output
Request a quote

Drinking water safety

Routine checks of turbidity, pH, bacteria and key contaminants confirm that treated and distributed water stays safe from the treatment plant to the consumer tap.

Wastewater and reuse compliance

COD, nitrogen and phosphorus measurements show whether treated effluent meets discharge or reuse limits, an important step before using it for irrigation or landscaping.

Irrigation water suitability

Conductivity, pH and specific ions reveal salinity and toxicity risks in well and reclaimed water, helping farms protect soil structure and crop yields.

Aquaculture management

Dedicated aquaculture testing of dissolved oxygen, ammonia, nitrite, sulfide and salinity helps farms keep stock healthy and respond quickly when water conditions change.

Frequently Asked Questions

What is the difference between the benchtop and portable COD analysers?

Both digest and measure COD, ammonia nitrogen, total phosphorus and total nitrogen. The benchtop version stores more curves and records for busy laboratories, while the portable version runs on battery or vehicle power for testing at the sampling site.

Can bacteria be tested outside the laboratory?

Yes. The portable bacteria kit includes a vacuum filtration set and culture holder, so samples can be filtered and incubated in the field for total bacteria, E. coli and other indicator organisms.

How often should pH and conductivity meters be calibrated?

Calibrate with fresh standard buffers or solutions at the start of each working day, or more often when accuracy is critical, and record each calibration as part of the laboratory quality system.

Equip your water laboratory

Tell us your water sources, parameters and sample load. ASFAN will recommend benchtop and field equipment and prepare a quotation.

Request a Quote
Chat with us on WhatsApp