Containment and clean-air equipment that protects people, samples and the environment when working with microorganisms, chemicals and sterile cultures.

Laboratory Safety & Clean Air Equipment

Protecting people, samples and results

Laboratory safety and clean air equipment controls airflow to keep hazards contained and work areas clean. Class II A2 biological safety cabinets protect the operator, the sample and the room when handling pathogens and cell cultures. Chemical fume hoods exhaust vapours from acids, solvents and digestion. Laminar flow clean benches provide HEPA-filtered air for sterile work such as media preparation and plant tissue culture, while air showers and mobile air purifiers reduce particles entering or circulating in clean areas. Diagnostic, microbiology, plant protection, veterinary, food and university laboratories rely on them. ASFAN supplies, installs and supports this equipment and helps specify complete laboratories.

Laboratory Safety & Clean Air Equipment

Laminar Flow Clean Bench

Laminar Flow Clean Bench

Clean bench with HEPA-filtered laminar airflow reaching class 100 (US Federal Standard 209b), with a semi-closed glass door, adjustable air volume, LED/LCD control panel and stainless-steel work area.

  • Purification efficiencyClass 100 (US Federal Standard 209b)
  • Average air speed0.3–0.6 m/s (adjustable)
  • Average colonies≤ 0.5 pcs/dish·h
  • Noise≤ 60 dB(A)
Features & full specifications

Key features

  • Semi-closed glass door blocks external airflow and odors
  • Adjustable air volume
  • LED/LCD control panel
  • Stainless-steel work area
  • Lighting and germicidal UV lamp

Available configurations

  • Single-person, 850×570×1550 mm, work area 700×500×500 mm, 0.3 kW, 85 kg
  • Single-person (alternate design), 850×570×1550 mm, work area 700×450×500 mm, 0.3 kW, 85 kg
  • Single-person, 1050×680×1600 mm, work area 870×650×520 mm, 0.4 kW, 150 kg
  • Single-person (alternate design), 1050×680×1600 mm, work area 870×650×520 mm, 0.4 kW, 150 kg
  • Double-person, 1540×680×1600 mm, work area 1360×650×520 mm, 0.8 kW, 200 kg

Technical specifications

Purification efficiencyClass 100 (US Federal Standard 209b)
Average air speed0.3–0.6 m/s (adjustable)
Average colonies≤ 0.5 pcs/dish·h
Noise≤ 60 dB(A)
Vibration half-peak≤ 3 µm (X·Y·Z)
Power supply220 V 50 Hz
Power0.3 / 0.4 / 0.8 kW
Weight85 / 150 / 200 kg
Lighting / germicidal lamp15 W / 20 W / 30 W
Request a quote
Chemical Fume Hood

Chemical Fume Hood

Ducted chemical fume hood that uses negative pressure to exhaust experimental gases from the working area. Frame of fireproof high-density board with a stainless steel (or PP) work area.

  • Discharge (face) velocity0.25–0.45 m/s adjustable
  • Inlet pressure>0.5 Pa
  • Power400–800 W
  • Power supplyAC 220 V / 50 Hz
Features & full specifications

Key features

  • Frame of 50% fireproof high-density board; good sealing, strong and durable
  • Negative-pressure design discharges experimental gas from the working area
  • Digital LCD control panel with fast/medium/slow three-speed fan
  • Work area of SUS304 brushed stainless steel (or PP), easy to clean and corrosion resistant
  • Standard 160 mm diameter, 1 m exhaust pipe and elbow
  • Five-hole power socket in the work area
  • Optional work-area sink and faucet

Available configurations

  • 1.2 m wide: 1030×700×600 mm work area, 400 W, 160 kg
  • 1.5 m wide: 1330×700×600 mm work area, 800 W, 180 kg
  • 1.8 m wide: 1630×700×600 mm work area, 800 W, 200 kg

Technical specifications

Discharge (face) velocity0.25–0.45 m/s adjustable
Inlet pressure>0.5 Pa
Power400–800 W
Power supplyAC 220 V / 50 Hz
Working area (W×D×H)1030×700×600 mm to 1630×700×600 mm
Overall dimensions (W×D×H)1200×760×1950 mm to 1800×760×1950 mm
Weight160–200 kg
Fluorescent / UV lamp20 W×1, 30 W×1 or 20 W×2
Request a quote
Benchtop Laminar Flow Hood

Benchtop Laminar Flow Hood

Small benchtop clean bench (Class 100) that can be placed on a general workbench, offered with horizontal or vertical airflow in two widths. The fan speed is switched by remote control to keep the wind speed in the working area ideal.

  • Clean gradeClass 100 (US Fed. 209E)
  • Bacteria count≤0.5 per plate·hour (90 mm plate)
  • Noise≤62 dB
  • Power supplyAC 220 V / 50 Hz
Features & full specifications

Key features

  • Vertical manifold, quasi-closed glass damper, easy to operate
  • Compact; fits on a general workbench in small labs
  • Remote-control fast/slow fan switching keeps working-area wind speed ideal
  • Horizontal-flow and vertical-flow versions

Available configurations

  • Horizontal airflow, 650 mm wide
  • Horizontal airflow, 850 mm wide
  • Vertical airflow, 650 mm wide
  • Vertical airflow, 850 mm wide

Technical specifications

Clean gradeClass 100 (US Fed. 209E)
Bacteria count≤0.5 per plate·hour (90 mm plate)
Noise≤62 dB
Power supplyAC 220 V / 50 Hz
Average wind speed0.25-0.45 m/s
Working area485 x 475 x 455 mm to 685 x 475 x 455 mm
Overall dimensions640 x 530 x 846 mm to 840 x 530 x 845 mm
Lamps8 W fluorescent x1 / 10 W UV x1
HEPA filter480 x 460 x 38 mm to 680 x 460 x 38 mm
Request a quote
Class II Biological Safety Cabinet (70% Exhaust, A2 type)

Class II Biological Safety Cabinet (70% Exhaust, A2 type)

Class II biological safety cabinet with 70% air exhaust and 30% recirculation, vertical laminar flow and negative pressure, for microbiology labs in medicine, pharmacy and scientific research. Offered in 1.0, 1.3 and 1.6 m widths.

  • CleanlinessClass 100 (US Fed. 209E), ≥0.5 µm ≤3.5 particles/L
  • Colonies≤0.5 pcs/dish·hour (Ø90 mm plate)
  • Downflow wind speed0.26-0.38 ±0.025 m/s
  • Front inflow speed0.55 ±0.025 m/s
Features & full specifications

Key features

  • Ergonomic 10° inclined front
  • 30% air recirculation / 70% exhaust with vertical laminar negative pressure to avoid cross contamination
  • Spring-balanced movable front door
  • Exhaust filter meeting national standards
  • Contact switch voltage adjustment keeps working-area wind speed stable
  • LED control panel
  • 304 stainless steel work area

Available configurations

  • 1.0 m working width, single operator
  • 1.3 m working width, two operators
  • 1.6 m working width, two operators

Technical specifications

CleanlinessClass 100 (US Fed. 209E), ≥0.5 µm ≤3.5 particles/L
Colonies≤0.5 pcs/dish·hour (Ø90 mm plate)
Downflow wind speed0.26-0.38 ±0.025 m/s
Front inflow speed0.55 ±0.025 m/s
Noise≤62 dB(A)
PowerAC220 V / 50 Hz, 800 W max
Biological safetyPersonnel CFU ≤10; product CFU ≤5; cross-contamination CFU ≤2
Working area1000 x 650 x 620 mm to 1600 x 650 x 620 mm
Overall dimensions1195 x 720 x 1950 mm to 1795 x 720 x 1950 mm
Weight150-250 kg
Request a quote
Laboratory Cleanroom Air Shower

Laboratory Cleanroom Air Shower

Microcomputer-controlled air shower with LED digital display, automatic showering, explosion-proof glass, primary filter and 99.995% HEPA filter that removes dust carried by people at high speed. Used in electronics, machinery, medicine, food, packaging, bioengineering and research; custom sizes available.

  • ConfigurationsSingle-person single-blow, single-double, double-single
  • Nozzles6-12, Ø30 mm
  • Nozzle air speed15-20 m/s
  • Filter efficiency≥99.99% at <0.5 µm
Features & full specifications

Key features

  • Microcomputer control with LED digital display
  • Automatic air shower cycle
  • Explosion-proof glass
  • Primary filter plus 99.995% high-efficiency filter
  • Low energy consumption and easy maintenance
  • Custom sizes available

Available configurations

  • Single person, single-side blowing, 6 nozzles
  • Single person, double-side blowing, 12 nozzles
  • Two persons, 9 nozzles, 1200 mm deep
  • Single person, 6 nozzles, 750 mm wide area

Technical specifications

ConfigurationsSingle-person single-blow, single-double, double-single
Nozzles6-12, Ø30 mm
Nozzle air speed15-20 m/s
Filter efficiency≥99.99% at <0.5 µm
Shower area (W x D x H)700 x 760 x 1900 to 700 x 1200 x 1900 mm
Overall size (W x D x H)1050 x 760 x 2050 to 1300 x 760 x 2050 mm
PowerAC 3N 220 V 50 Hz, 550-2200 W
Weight200-500 kg
Request a quote
Laboratory Mobile Air Purifier

Laboratory Mobile Air Purifier

Mobile air self-purifying unit with primary filter, fan and HEPA filter in a varnished cold-rolled steel case, for local purification where cleanliness of class 10,000-100,000 is required, such as sterile rooms, labs and food/beverage plants.

  • Filtration efficiency≥99.97% @ ≥0.5 µm
  • Average wind speed1.2-2 m/s ±20%
  • Rated air volume1000 m³/h
  • Power supplyAC220 V / 50 Hz
Features & full specifications

Key features

  • Cold-rolled steel case with varnish finish
  • Primary filter, supply static pressure box, HEPA filter and flow plate
  • Wind-speed regulation device
  • Outlet up to class 1,000; bench up to class 10,000
  • Casters with adjustable jacks for easy relocation
  • Variable wind speed and multi-shift timer

Technical specifications

Filtration efficiency≥99.97% @ ≥0.5 µm
Average wind speed1.2-2 m/s ±20%
Rated air volume1000 m³/h
Power supplyAC220 V / 50 Hz
Power350 W
HEPA filter760 x 610 x 38 mm
Dimensions845 x 500 x 1245 mm
Noise≤62 dB(A)
Request a quote

Working safely with pathogens

Biological safety cabinets contain aerosols when plant, animal and foodborne pathogens are cultured or tested, protecting staff and preventing release into the wider environment.

Chemical exposure control

Fume hoods draw acid fumes and solvent vapours away from the operator during digestion, extraction and reagent preparation, supporting a safer working atmosphere.

Sterile culture work

Laminar flow benches deliver clean air over the work surface, reducing contamination in plant tissue culture, media preparation and microbiological plating.

Cleaner controlled areas

Air showers remove dust from clothing at the entrance to clean areas, and mobile purifiers improve local air cleanliness in sterile rooms and food production zones.

Frequently Asked Questions

Is a laminar flow bench the same as a biological safety cabinet?

No. A laminar flow bench protects only the sample, blowing clean air towards the operator. A Class II biological safety cabinet protects the operator, the sample and the environment, and is required when handling infectious material.

What does Class II A2 mean?

It is a common biological safety cabinet type in which about 70 percent of the air is exhausted through a HEPA filter and 30 percent recirculated, with an inward airflow at the front opening for operator protection.

Do fume hoods need external ducting?

The chemical fume hood offered is ducted and is supplied with an exhaust pipe and elbow. The exhaust route to outside the building should be planned with the laboratory layout before installation.

Plan a safe laboratory

Tell us the materials you handle and your room layout. ASFAN will recommend suitable containment and clean-air equipment and prepare a quotation.